Distributor Products:

Oxygen analyzer

Click image for more information

 

Rapidox 1100Z

The Rapidox 1100Z is a zirconia oxygen analyser that allows fast and accurate oxygen analysis over the range 1ppm to 100% O2. The analyser provides continuous on-line oxygen analysis, with a typical response time of less than 5 seconds for a 90% response to a step change in gas composition. It also includes an internal pressure sensor to compensate for small variation in gas pressure. Various applications are possible, including, including low level O2 monitoring in laboratories and inert gas purity measurements.

   

Rapidox 1100E

The Rapidox 1100E oxygen analyser gives accurate oxygen analysis over the oxygen range 0 to 100% O2 with a resolution of 0.01%. The Rapidox 1100E contains a top-of-the-range Yuasa electrochemical O2 sensor which has an estimated lifetime of 5 years. Like all the 1100 range the unit has programmable alarm circuits, programmable analogue outputs, easy calibration (user selectable gases), RS232 communications and complete communication/ data-logging software.

   

Rapidox 1100L

The Rapidox 1100L is designed for low range O2 analysis where a traditional zirconia sensor may not be suitable. The 1100L contains a German engineered ppm electrochemical oxygen cell which measures from 0.1ppm to 1% O2. This analyser is most suitable when the user wants to measure O2 in a gas mixture containing VOCS, solvents, helium or fuels. All of the Rapidox 1100 range of oxygen analysers have pumps with variable flow rate, can be supplied panel mounted and equipped with the gas inlets and outlets on the rear of the instrument.

   

Rapidox 2100

The Rapidox 2100 is a portable oxygen analyser that is perfect for high temperature gas measurements or measuring gas in vacuum. From the display to the outputs, all features are fully user programmable using the keypad on the front panel, or the software provided. Easy to use and simple to calibrate using your choice of up to three gases, the Rapidox 2100 offers exceptional performance and flexibility using a rugged, long-life zirconia oxygen sensor.

   

Rapidox 2100 OEM

The Rapidox 2100 OEM uses the same sensor as the Rapidox 2100, which allows fast and accurate oxygen analysis over the full oxygen range (10-20 ppm to 100%O2). The analyzer provides continuous on-line oxygen analysis, with a typical response time less than 5 seconds for a 90% response to a step change in gas composition. The Rapidox 2100 OEM offers analyser performance at a very competitive price. Like all the 2100 range it is supplied with full Windows software for easy data logging and live time graphing.

   

Rapidox 2100W

Supplied in an IP65 weather proof housing with a transparent polycarbonate hinged window, the Rapidox 2100 Wallmount includes all the features of the bench-mounted version and is built to suit a static application. The zirconia oxygen sensor is fitted inside a bespoke steel cabinet with a flow gauge, room for a printer and auxiliary sensors. Additional sensors can be fitted via the auxiliary input on either the 2100 or the 2100W models which can be configured to read pressure, vacuum or dew-point.

   

Rapidox 3100Z

The Rapidox 3100Z oxygen analyser allows fast and accurate O2 analysis down to sub-ppm levels. All models in the 3100 range are designed to provide continuous in-line oxygen analysis and are fitted with a motor-driven sample pump. This precision range of analysers comes with fully programmable alarm circuits, programmable analogue outputs, easy calibration, RS232 / RS485 communications, a type K thermocouple and a full set of communications and data-logging software.

   

Rapidox 3100E/L/Z AB

The Rapidx 3100A/B are designed to measure O2 and either CO2 or CO. The analysers utilise state of the art infrared gas detection cards to measure CO2 or CO and are available with any of the O2, a Yuasa electrochemical cell which offers a range of 0.01-100% and finally the L cell which utilises a German engineered ppm electrochemical sensor with a range of 0.1ppm to 1%. Users can also benefit from a large range of CO/CO2 cards.

               

Rapidox 3100E/L/Z D

The Rapidox 3100D uses a dewpoint sensor alongside any of the available oxygen sensors. This enables the user to plot the moisture content of their gas mixture along with the O2 content. As with the other models in the 3100 range full pressure, excluding the H2O sensor in the Rapidox 3100D, and temperature compensation are included. All the Rapidox dual gas analysers can data logboth gases and can use MS-Excel logging software. A variety of filters also available, allowing the 3100 range to be used in a large number of applications .

   

Rapidox 3100C

The Rapidox IR SF6 Analyser is the latest high precision gas analyser designed for controlling and monitoring the quality of SF6 in gas insulated sub-station and circuit breakers. The analyser not only measures the SF6 gas content in air or nitrogen over the full range, but also measures the moisture and SO2 content. The analyser simultaneously measures SF6 (0-100%), SO2 (0-100ppm) and H2O (-100 to +20°Cdp). All three gases can be monitored and data-logged simultaneously with readings given extremely quickly.

   

Rapidox 3100 C kit

The Rapidox 3100C is also available as a complete portable kit allowing engineers to carry all the equipment they need in one handy case. This includes a handle for the unit itself, a set of DN8 and DN20 DILO fittings with 2m hose and a thermal printer. In addition to the standard 3100-C a battery powered model is now available, making the unit fully portable. With up to eight hours between charges this unit is perfect for sampling multiple sites quickly and efficiently. Both battery / mains powered units are available in single gas models.

   

Rapidox SF6 Bag

The Rapidox SF6 recovery bag is designed to store samples of SF6 until they can be properly recycled. The bag can hold up to 80 litres of SF6 at standard pressure, allowing many hours of testing before the bag needs to be emptied. Once the user has finished or the bag has become full it can be returned to a recycling facility. The gas fitting has an adapter inbuilt to allow the stored gas to be decanted into a permanent storage bottle. The bag is constructed from extremely though and durable polyamide material.